How often should barriers and guards be inspected?
Check barriers and guards after every forklift impact and carry out a full inspection at least every 12 months — you can do it yourself using the list below. Replace an element if the impact has deformed it or cracked its welds.
01 Inspection checklist
| Element | What to check | When | What to do |
|---|---|---|---|
| Anchors and base plates | loose or pulled-out anchors, cracked concrete at the base plate | after an impact and once a year | replace the anchors; chemical anchors for cracked floors |
| Tubes and handrail | deformation, dents, cracked welds | after an impact and once a year | replace the element (production 7–14 days, galvanised 14–28 days) |
| Self-closing gate | whether the leaf returns to the closed position by itself | once a year | adjust the hinge closing force |
| Coating | chipped coating, signs of rust | once a year | report it with photos — reply within 24 h |
| Warning stripes | visibility of RAL 1023 / RAL 9005 | once a year | renew the marking |
02 After a forklift impact
After every impact check the element and its base plate with the anchors. If the tube is deformed or the anchors have loosened, report the damage — we will select the element and give you the price and replacement date.
Send three photos with the report: the whole location, the damage close up and the base plate with the anchors. If you know the dimensions or our invoice number, add them to the description.
03 Annual inspection
You can do the inspection yourself: go through the checklist at the start of this guide and note any elements that are deformed, have cracked welds or loose anchors.
You can also order the inspection from us — we check the anchors and base plates, tube deformation, the coating condition and the visibility of the warning stripes, and afterwards you receive a list of elements to repair or replace.
04 When to replace an element
An element should be replaced if the impact has deformed it or cracked its welds. We replace only the damaged element — we make it in our own plant in 7–14 days, or 14–28 days galvanised.
05 Documentation
We record the anchor type in the installation report — useful when the anchors are replaced.
FAQ Frequently asked questions
How often should barriers be inspected?
Check the damaged element after every forklift impact and carry out a full inspection at least once a year.
Can I do the inspection myself?
Yes. Go through the checklist in this guide; if you find a deformed element or cracked welds, report the damage with photos.
When must an element be replaced?
When the impact has deformed it or cracked its welds.
Do you replace only the damaged element?
Yes. Based on the photos we select the element, make it in our own plant (7–14 days, galvanised 14–28 days) and replace it on site or ship it for self-installation.
How quickly will I get a repair quote?
We reply to enquiries with photos within 24 h.
Products in this guide
Where the numbers come from
- Inspection scope and damage reports: B.S.G service page.
- Anchoring: B.S.G impact protection product pages.